BLOOD BAG SYSTEMS

NOTE: PVC material - Roll Welding Film
Blow extrude also available, Add "B" at the end of item code

Optional Accessories:

  • Needle Protector
  • Sample Pouch + Collection Tube
    Size Solution
Single bag   250ml CPDA1,39ML
Needle -16G   350ml CPDA1,49ML
    450ml CPDA1,63ML
    500ml CPDA1,70ML
    Size Solution
Double bag   250ml CPDA1,39ML
Needle -16G   350ml CPDA1,49ML
    450ml CPDA1,63ML
    500ml CPDA1,70ML
    Size Solution
Triple bag   250ml CPDA1,39ML
Needle -16G   350ml CPDA1,49ML
    450ml CPDA1,63ML
    500ml CPDA1,70ML
    Size Solution
Triple bag   250ml CPDA1,39ML SAGM-56ML
Needle -16G   350ml CPDA1,49ML SAGM-78ML
    450ml CPDA1,63ML SAGM-100ML
    500ml CPDA1,70ML SAGM-111ML
    Size Solution
Quadruple bag   250ml CPDA1,39ML
Needle -16G   350ml CPDA1,49ML
    450ml CPDA1,63ML
    Size Solution
Quadruple bag   250ml CPDA1,39ML SAGM-56ML
Needle -16G   350ml CPDA1,49ML SAGM-78ML
    450ml CPDA1,63ML SAGM-100ML


Blood Bag Product Introduction

  • High quality blood bags are designed for most secure blood collection, separation, preservation and transfusion.

Standard Features:

  • Flexible pre-sterilized,pyrogen, non toxic, non-hemolytic, biocompatible material.
  • No risk of contamination and air embolism (closed system).
  • Slit on both sides of the bags can accommodate 5-10ml volume test tubes.
  • The capacity of the bag is enough to prevent any rupture of the bag from the seam when it is filled to the requisite volume of blood.
  • High quality, peel-resistant label provides for convenient writing.
  • Ultra thin walled 16G venipuncture needle is optimal for reducing donor pain, optional needle protection system can keep the operator always safe.
  • CPDA-1 or CPD/SAG-M anticoagulant preservation for 35 days or 42days whole blood storage or red cell storage respectively.
  • Easy to break off valve allows plasma transfer to both directions freely.
  • Round bag shape for increasing yield of blood components during separation.
  • Sterilized by high pressure, high temperature steam.
  • Optional Components:
  • Attached blood sampling device.
  • Needle protector.
  • "Y" injection port.
  • In-line leukocyte reduction filter.
  • Platelet storage bag (platelet storage for 3 to 7 days).
  • Type of outlet ports (twist off or tear off).
  • Volume of primary bag and satellite bags.
  • Customize Design

Anticoagulant Solution Choices

Solution Purpose Whole blood/red cell storage Additive concentration (per 100ml) Performance  
CPD Anticoagulation and storage of blood 21 days Citric acid (anhydrous) 0.299g Prevent coagulation of blood
Sodium citrate (dihydrate) 2.63g Adjust pH
Monobasic sodium phosphate (monohydrate) 0.222g Nutrition source of red cell
Dextrose (monohydrate) 2.55g Supports ATP production
Water for injection q.s100ml  
CPDA 1 Anticoagulation and storage of blood 35 days Citric acid (anhydrous) 0.299g Prevent coagulation of blood
Sodium citrate (dihydrate) 2.63g Adjust pH
Monobasic sodium phosphate (monohydrate) 0.222g Nutrition source of red cell
Dextrose (monohydrate) 3.19g Supports ATP production
Adenine 0.0275g Supports to maintain ATP level
Water for injection q.s100ml In red cell
SAGM Red cell preservation 42 days Dextrose (monohydrate) 0.900g Nutrition source of red cell
Sodium chloride 0.877g Adjust osmotic pressure
Adenine 0.0169g Supports to maintain ATP level
D-mannitol 0.525g In red cell
Water for injection q.s.100ml Supports integrity of red cell membrane (to avoid haemolysis)